Adam-5000
Modular I/O System
Adam-5000 Models Available
Rows Per Page:
Pageof 4
Adam-5000 Series
ADAM-5050
Modular I/O System
- Digital input: Support Dry/Wet Contact
- Digital output: Open Collector to 30 V, 450 mW max. load
- I/O Type: bit-wise selectable by DIP switch
- Power consumption: 0.35 W (typical); 1.2 W (max)
- Channels: 16
Product Overview
Modular I/O System
Key Features
Adam-5000 Series
ADAM-5051
Modular I/O System
- Input voltage: 30 Vmax
- Circuit type: Pull-Up current: 0.5 mA (Source Type)
- Power consumption: 0.53 W
- Channels: 16
- DAQ Type: REMOTE I/O
Product Overview
Modular I/O System
Key Features
Adam-5000 Series
ADAM-5056D
Modular I/O System
- Operating voltage: 30 Vmax
- Digital output: Open collector to 30 V, 100 mA max. load
- Power consumption: 0.5 W (typical); 0.84 W (max.)
- Power dissipation: 300 mW for each channel
- LED indicator: On: Output logic level "1"
Product Overview
Modular I/O System
Key Features
Adam-5000 Series
ADAM-5024
Modular I/O System
- Accuracy: ±0.1% of FSR for current output
- Effective resolution: 12-bit
- Isolation voltage: 3000 VDC
- Output range: 0 ~ 20 mA, 4 ~ 20 mA, 0 ~10 V
- Resolution: ±0.015% of FSR
Product Overview
Modular I/O System
Key Features
Adam-5000 Series
ADAM-5017P
Modular I/O System
- Accuracy: Voltage mode : ±0.1% or better, Current mode : ±0.2% or better
- High Common Mode: 200 VDC
- Over Voltage Protection: ±60 VDC
- Isolation Voltage: 3,000 VDC
- CMR @ 50/60 Hz: 92 dB min.
Product Overview
Modular I/O System
Key Features
- 8-ch Analog Input Module with Independent Input Range
Adam-5000 Series
ADAM-5018
Modular I/O System
- Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 Hz
- Sampling Rate: 10 samples/sec. (total)
- High Common Mode: 2000 VDC
- Isolation Voltage: 3,000 VDC
- CMR @ 50/60 Hz: 92 dB min
Product Overview
Modular I/O System
Key Features
- Fault and Overvoltage Protection: Withstands over voltage up to ±35 V
Adam-5000 Series
ADAM-5013
Modular I/O System
- Accuracy: ±0.1% or better
- Effective resolution: 16-bit
- Input connections: 2, 3 or 4 wire
- Sampling rate: 10 samples/sec. (total)
- Isolation voltage: 3000 VDC
Product Overview
Modular I/O System
Key Features
Adam-5000 Series
ADAM-5000/485
Modular I/O System
- DAQ Type: REMOTE I/O
- DI: No
- DO: No
- AI: No
- AO: No
Product Overview
Modular I/O System
Key Features
- RS-485 communication for easy installation and networking
- 4 slots for up to 64 points data monitoring card control in one module
- Supports ADAM ASCII protocol or Modbus®/RTU protocol
- Supports Modbus/RTU protocol with user-defined Modbus address
- Extensive software support, includes windows DLL drivers, OCX drivers, OPC server and popular HMI/SCADA software drivers
- Seamlessly integrated with easy-to-use ADAMView data acquisition software
Adam-5000 Series
ADAM-5000/TCP
Modular I/O System
- DAQ Type: REMOTE I/O
- DI: No
- DO: No
- AI: No
- AO: No
Product Overview
Modular I/O System
Key Features
- 10/100Base-T auto-negotiation high-speed communication port
- Provides C and .NET class library to develop applications
- Windows utility- I/O modules configuration and calibration- Network auto searching- Data stream setting- Current status monitoring and alarm trigger
- 8 I/O slots for up to 128 points data monitoring and control
Adam-5000 Series
ADAM-5000L/TCP
Modular I/O System
- DAQ Type: REMOTE I/O
- DI: No
- DO: No
- AI: No
- AO: No
Product Overview
Modular I/O System
Key Features
- 10/100Base-T auto-negotiation high-speed communication port
- Provides C and .NET class library to develop applications
- Windows utility- I/O modules configuration and calibration- Network auto searching- Data stream setting- Current status monitoring and alarm trigger
- ADAM-5000 PC-based controllers, including the ADAM I/O series system, and ADAM-5560CE/KW Micro PAC, feature an Intel Atom D510 CPU along with control specific features such as watchdog timer, battery backup RAM and deterministic I/O. ADAM-5560KW PC-based controllers support 5 standard IEC 61131-3 programming languages in CE 5.0. With the optional HMI Software and built-in VGA port, this remote I/O module can avoid using additional SCADA PC’s in their applications
Rows Per Page: